Detektor Khusus Konvensional, Alas, dan Wadah


 
D285DH Duct smoke head, 2-/4-wire, 12/24V
  • Commercial or residential applications
  • Two-wire or four-wire application, depending on base
  • Chamber Check rapid-flash LED Automatic Trouble Indication reports contaminated chamber
  • Flashing LED power indicator
  • Steady-On LED alarm indicator
  • Modular design
 
 
D342 Family four‑wire duct smoke detector housings
  • For 1 ft. (30.5cm) to 10 ft. (3 m) ducts with air velocity between 300 ft./min. to 4000 ft./min. (1.52 m/s to 20.3 m/s)
  • Easy duct tube installation through the housing cuts installation time
  • Detector test and reset without removing covers
  • Clear cover allows quick visual inspection
  • Tube filters, dust immune smoke detector, and easy disassembly for cleaning reduce maintenance time and cost
 
 
D296 Smoke detector, long-range beam 24V
  • Operates over distances between 30 ft (9 m) and 350 ft (107 m)
  • Six levels of switch-selectable sensitivity
  • Built-in alignment sights and tamper protection
  • Automatic range adjustment, signal synchronization, and contamination adjustment
  • Remote indicator plate annunciates detector status and provides test points for voltage monitoring
 
 
D297 Smoke detector, long-range beam, 12V
  • Operates over distances between 30 ft (9 m) and 350 ft (107 m)
  • Six levels of switch-selectable sensitivity
  • Built-in alignment sights and tamper protection
  • Automatic range adjustment, signal synchronization, and contamination adjustment
  • Remote indicator plate annunciates detector status and provides test points for voltage monitoring
 
 
D284 Ultraviolet flame detector, 24V
  • Highly reliable, long-lasting ultraviolet (UV) receptor tube
  • Low power consumption
  • Can be mixed with other detector types on the control panel's initiation detection circuit (IDC)
  • Easily maintained; can be cleaned without disassembly
 
 
D382 Combustible Gas Detector (Macurco GD-2A)
  • 12 VDC/VAC or 24 VDC/VAC operation
  • Self-purging semiconductor sensor requires no maintenance or recalibration
  • SPDT (Form C) alarm Relay and SPST (Form A) trouble relay designed for seamless connection to control panels or other devices
  • Installer selectable self-restoring or latching functionality
  • Red and Green LED status indicators
 
 
FCC-380 CO detector (Macurco CM-E1)
  • Solid state sensor provides maintenance-free operation
  • Microcomputer control provides virtual automatic operation
  • 9 VDC to 32 VDC operation is compatible with 12‑V and 24-V systems
  • Can quickly test CO sensor on site
  • Three-color LED status display
  • Four‑wire technology for connection to any UL Listed control panel